Systec Autoclaves
Easy and safe. When the lid is closed, the lid is automatically locked by a circumferential ring system. A special lip seal made of heat resistant silicone provides reliable sealing. As steam pressure builds the seal becomes tighter.
Features
V Series
Chamber Size
| Type | V-40 | V-55 | V-65 | V-75 | V-95 | V-100 | V-120 | V-150 |
| Chamber Dimensions in mm (diameter x depth) |
344x450 | 344x600 | 400x500 | 400x600 | 400x750 | 500x500 | 500x600 | 500x750 |
| Chamber Volume in Liters | 40 | 55 | 65 | 75 | 95 | 100 | 120 | 150 |
Loading Capacity
Erlenmeyer Flasks
| Type | V-40 | V-55 | V-65 | V-75 | V-95 | V-100 | V-120 | V-150 |
| 250 ml | 3 x 11 | 4 x 11 | 3 x 14 | 4 x 14 | 5 x 14 | 3 x 22 | 4 x 22 | 5 x 22 |
| 500 ml | 2 x 7 | 3 x 7 | 2 x 8 | 3 x 8 | 4 x 8 | 2 x 14 | 3 x 14 | 4 x 14 |
| 1000 ml | 2 x 4 | 2 x 4 | 2 x 5 | 2 x 5 | 3 x 5 | 2 x 8 | 2 x 8 | 3 x 8 |
| 2000 ml | 3 | 2 x 3 | 4 | 2 x 4 | 2 x 4 | 6 | 2 x 6 | 2 x 6 |
| 3000 ml | 1 | 1 | 2 | 2 | 2 x 2 | 4 | 4 | 2 x 4 |
| 5000 ml | 1 | 1 | 1 | 1 | 2 x 1 | 3 | 3 | 2 x 3 |
Schott Duran Media Flasks
| Type | V-40 | V-55 | V-65 | V-75 | V-95 | V-100 | V-120 | V-150 |
| 250 ml | 3 x 17 | 4 x 17 | 3 x 20 | 3 x 20 | 5 x 20 | 3 x 30 | 3 x 30 | 5 x 30 |
| 500 ml | 2 x 11 | 3 x 11 | 2 x 15 | 3 x 15 | 4 x 15 | 2 x 22 | 3 x 22 | 4 x 22 |
| 1000 ml | 8 | 2 x 8 | 2 x 9 | 2 x 9 | 3 x 9 | 2 x 15 | 2 x 15 | 3 x 15 |
| 2000 ml | 4 | 2 x 4 | 5 | 2 x 5 | 2 x 5 | 8 | 2 x 8 | 2 x 8 |
| 5000 ml | 1 | 1 | 2 | 2 | 2 x 2 | 4 | 4 | 2 x 4 |
| 10000 ml | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 |
|
Innovative Automatic Safety Door Lock Easy and safe. When the lid is closed, the lid is automatically locked by a circumferential ring system. A special lip seal made of heat resistant silicone provides reliable sealing. As steam pressure builds the seal becomes tighter. The lid also opens easily – either at the push of a button or automatically at the end of a sterilization cycle. The door-locking system is temperature dependent and adheres to national and international safety standards. The door remains locked as long as there is excess pressure in the chamber. The lid, like other parts of the pressure vessel and housing, is made of stainless steel. The modern design faceplate, which also contains the control panel, display and part of the control technology, is made of heat resistant and insulated plastic. There is no risk of the operator coming into contact with hot components. |
![]() |
|
|
|
|
|
| Pressure-safe up to 5 bar/150 °C. Tomorrow’s process requirements are addressed in today’s design! The Systec V-Series autoclaves are the first of its kind to be designed for higher pressures and temperatures. The standard pressure chamber is designed for 5 bar/150 °C. If the expanded pressure and temperature model is selected as an option, all control and safety components are adapted to the higher temperature and pressure. This option may be retrofitted to existing V- series autoclaves. | ![]() |
|
| Systec V-Series autoclaves are equipped direct from the factory for sterilization temperatures up to 140°C and 4 bar of pressure. | ![]() |
|
| Controls – new generation. Microprocessor and software. The Systec V-Series autoclaves have “comprehensive intelligence”: Pressure is controlled via an electronic pressure transducer. Additionally, there is a flexible temperature sensor in the sterilization chamber or in a reference vessel (for liquids) and another sensor at the coldest part of the chamber, the condensate outlet. The microprocessor, specially developed for our laboratory autoclaves, controls all relevant functions such as steam pressure, temperature and sterilization time as well as optional rapid cooling, pre / post-vacuum and drying. Menu-presented instructions in easy to read text form. Membrane keyboard with acoustic confirmation signal. Ergonomically located in a logical and easy to operate position. |
![]() |
|
|
Design – pure innovation! Steam generation! – No heating elements and no reservoir for dirty water in the chamber – With stand-by pre-heating option, only 10 min. heating time to 121° C with an empty chamber – Improved removal of air from the empty chamber via pulsed heating (rapid attainment of optimal steam atmosphere, even without a vacuum) – Accuracy better than ± 0.3 C with empty chamber – Quicker cooling as neither hot water in the chamber nor the separate steam generator need be cooled – After cooling, steam is immediately available for the next sterilization run. |
![]() |
|
| Condensation instead of steam removal! Exhaust steam is condensed automatically via a PT 100-regulated cooling system. This prevents odors and protects waste water piping. Quality materials quality manufacturing! The pressure vessel is made of corrosion-resistant electro-polished stainless steel 1.4571 (V4A) AISI 316 Ti and therefore very easy to clean. Autoclave framework and housing are also made of stainless steel. The highly efficient, high-quality Hanno-Tect insulation material releases no particles and therefore the Systec V-Series is ideal for use in clean room environments. |
|
|
|
Further standard features: – Flexible temperature sensor PT-100 for a reference vessel – Medium temperature triggering of sterilization time – Autofill – automatic filling with demineralized water feed for steam generation – Start by clock – timer for programming starting time – Collecting point for all outlet pipes – Venting valve – Baseplate in the chamber for vessels, baskets etc. |
![]() |
|
Specs
| V-Series Model | V-40 | V-55 | V-65 | V-75 | V-95 | V-100 | V-120 | V-150 |
| Chamber dimensions (diameter x depth) mm |
344 x 450 | 344 x 600 | 400 x 500 | 400 x 600 | 400 x 750 | 500 x 500 | 500 x 600 | 500 x 750 |
| Chamber Volume (Liters) | 40 | 55 | 65 | 75 | 95 | 100 | 120 | 150 |
| External Dimensions (W x H x D) mm |
500 x 920 x 740 | 500 x 920 x 740 | 550 x 855 x 775 | 550 x 960 x 780 | 550 x 1070 x 775 | 650 x 855 x 895 | 650 x 985 x 900 | 650 x 1070 x 895 |
| Max. working chamber pressure (bar) | -1 to +4 | -1 to +4 | -1 to +4 | -1 to +4 | -1 to +4 | -1 to +4 | -1 to +4 | -1 to +4 |
| Max. working chamber temp. (Celsius) | -10 to 150 | -10 to 150 | -10 to 150 | -10 to 150 | -10 to 150 | -10 to 150 | -10 to 150 | -10 to 150 |
| Max. working steam generator pressure (bar) | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
| Max. working steam generator temp. (Celsius) | 160 | 160 | 160 | 160 | 160 | 160 | 160 | 160 |
| Heating Capacity (Watts) | 9000 | 9000 | 9000 | 9000 | 9000 | 9000 | 9000 | 9000 |
| Voltage (Volts) | 240 | 240 | 3 x 220 | 3 x 220 | 3 x 220 | 3 x 220 | 3 x 220 | 3 x 220 |
| Power Requirement (Amps) | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
| Weight (kg) | 80 | 85 | 110 | 110 | 115 | 130 |
| Type of basket/insert | Stainless steel wire baskets | Stainless steel bucket for destructive sterilization | Stainless steel bucket w/ lid for destructive sterilization |
|||
| Dimensions (mm)(diameter x height) | Capacity | Dimensions (mm)(diameter x height) | Capacity | Dimensions (mm) | Capacity | |
| (diamter x height) | ||||||
| V-40 | 305 x 190 | 2 | 325 x 385 | 1 | - | - |
| V-55 | 305 x 280 | 2 | 325 x 385 | 1 | - | - |
| V-65 | 385 x 365 | 1 | 360 x 365 | 1 | 380 x 290 | 1 |
| 385 x 240 | 2 | |||||
| V-75 | 385 x 365 | 1 | 360 x 365 | 1 | 380 x 290 | 2 |
| 385 x 290 | 2 | |||||
| V-95 | 385 x 365 | 2 | 360 x 365 | 2 | 380 x 290 | 2 |
| 385 x 240 | 3 | |||||
| V-100 | 485 x 365 | 1 | 470 x 365 | 1 | 480 x 340 | 1 |
| 485 x 240 | 2 | |||||
| V-120 | 485 x 365 | 1 | 470 x 365 | 1 | 480 x 340 | 1 |
| 485 x 290 | 2 | |||||
| V-150 | 485 x 365 | 2 | 470 x 365 | 2 | 480 x 340 | 2 |
| 485 x 240 | 3 | |||||
| Process time for V-series Autoclaves | ||||||||
| Type | Size & number of vessels | Heating time (min) to 121oC | Cooling time (min) to 80oC without cooling system | Water Cooling | Water cooling and ventilation/forced convection | Cooling by ambient air ventilation | Spray Cooling | Laminar cooling |
| V-45 | ||||||||
| V-55 | ||||||||
| V-65 | 12 x 500 ml | 25 | 130 | 48 | 24 | 55 | 8 | 28 |
| V-75 | 6 x 1000 ml | 25 | 151 | 50 | 26 | 59 | 11 | 28 |
| V-95 | 18 x 1000 ml | 35 | 270 | 92 | 45 | 103 | 14 | 52 |
| V100 | 6 x 2000 ml | 33 | 263 | 98 | 51 | 108 | 17 | 57 |
| V150 | 42 x 500 ml | 44 | 230 | 94 | 48 | 106 | 13 | 52 |
Accessories
| Printer for documentation Print program type, batch number, date, time, temperature, pressure and sterilization phase. |
![]() |
| PC software For documentation during sterilization program. Download and save all cycle information. Additionally use for service and diagnosis of instrument electronics. |
![]() |
|
Stainless Steel closed basket for waste sterilization Used for waste sterilization |
![]() |
|
Stainless Steel wire mesh basket Used for sterilizing liquids, open containers, non-waste materials |
|
Air compressor – Silent 50 Used for quick cooling if compressed air is not available. |
|
Conductivity meter For validation of PT100 temperature probes |
|
Condensate collection vessel For units not connected to constant De-Ionized water supply |
|
Demineralization cartridge Stainless steel. For connection to “hard” water supply. |
|
Wheels with brakes Wheels (castors) attached to the bottom of the autoclave to facilitate moving the unit for convenience of cleaning or disconnecting. |
| Lift for heavy items The electrical lifting device with swiveled arm facilitates the loading and unloading of heavy items. The arm can be operated by a mobile control panel. The lifting device is firmly attached to the side of the autoclave. The swivel arm has a special grip for baskets so they remain stable when full. |
![]() |
Related Products