Whitley Workstation MG500

Anaerobic Hypoxic Systems


Features

Whitley Workstation MG-500

mg500__tg_airlock The Whitley Workstation MG-500 has a 540 plate capacity and is constructed of rigid acrylic (6mm thick front panels, 10mm thick side panels). The panels are chloroform annealed, creating a uni-body construction capable of withstanding positive pressure well in excess of the 4 PSI maintained constantly by the system.

Whitley Workstation MG-500 shown with optional airlock


Patented use of “oval” shaped gloveless entry ports allow the introduction of samples/materials by acting as a transfer airlock. This process allows the user to place their materials in the chamber while placing their hands in the chamber, reducing overall gas consumption considerably by not having to run a secondary airlock cycle. Evacuation and gassing of sleeves as well as opening of inner doors are controlled via the wireless footswitch.

copy_of_macsinsi

Patented use of Anotox (activated carbon impregnated with ferric hydroxide) for atmospheric conditioning. By using Anotox, the catalyst does not have to be removed and baked routinely. Anotox removes the Hydrogen Sulfide and volatile fatty acids (by-products of anaerobe metabolism) that poison the catalyst and can impede the growth of anaerobes.

The entire workstation is temperature controlled, allowing for temperatures between 4C and 44C. There is no need for extra incubators and loss of space efficiency.

Humidity is controlled automatically by an electronically controlled water removal system. Water is pumped to a container containing a silver-impregnated bacteriostatic wick to evaporate the water externally. There are no containers to empty. The humidity setting is user programmable. humidity_feature

The electronics and lighting are located in an external control housing. There is no need to compromise the workstation to change light bulbs or perform fuse replacement.

The 100 plate airlock is an option to the Whitley Workstation MG-500. The airlock cycle is electronically controlled and requires only a press of a button to operate. Catalyst dedicated to the airlock is housed internally and does not need to be changed or replaced.

The system uses a radio controlled footswitch to eliminate clumsy wiring. There is a manual override for use when necessary. macs_new_footswitch___operation_1c
copy_of_macsinla mg500
There are audible alarms to notify the user of low gas pressure, gas leaks, or power failure. The system is capable of maintaining anaerobiosis in the event of power loss for up to 24 hours.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specs

Whitley Workstation MG-500 Whitley Workstation MG-500 w/airlock
Dimensions
(L x D x H) in mm
1040 x 760 x 800 1570 x 760 x 840
Weight (Kg) 100 155
Gas Requirements 1 x ANO2
(10% H2, 10% CO2, 80% N2)
or 1 x ANO2 and Nitrogen
1 x ANO2
(10% H2, 10% CO2, 80% N2)
or 1 x ANO2 and Nitrogen
Gas Consumption
(on average)
4-6 weeks on 2000 lb tank 4-6 weeks on 2000 lb tank
Power Requirements 110 V, 50-60 Hz 110 V, 50-60 Hz
Working Capacity 540 x 90 mm plates 540 x 90 mm plates, airlock can transfer 90 x 90 mm plates

Options

 

Whitley Workstation Airlock Module

Three gases (TG) or mixed gas (MG) options available. For the fasted automated transfer time possible without compromising workstation conditions. Comes with sliding tray for easy transfer and has a 90 x 90mm plate capacity + space for sundries. The airlock cycle takes about 5 minutes to complete, once finished, the airlock is accessed frοm inside the chamber via a one-button elevator door.

(Available as an upgrade option to add to existing workstations)

airlockl

Refrigeration Unit

Designed to maintain a lower than normal temperature within the incubation and working area. The standard refrigeration unit is designed to operate at 8±10C when located in an ambient temperature of 21±20C. Other set temperatures are achievable, but require discussion with our product development department in advance.

refrigeration
Single Plate Entry System
For rapid transfer of individual plates into the chamber
single_plate_entry

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accessories

-Microscope and Bracket

A long focal length microscope, complete with bracket, fixtures and fittings.

microscope

-HEPA filtration unit

The HEPA filtration unit is available for all Whitley Workstation systems and recommended for BSL2 and higher safety environments. Atmosphere within the chamber is exhausted during normal cycle operations. This exhaust air can be filtered through the optional HEPA filtration system to avoid contamination of the lab environment. The system is comprised of dual stage filter units that are easily replaced every six months.

hepa_filter

-Orbis Microplate and Tube Shakers

The Orbis shaker is a compact choice of microplate shaker for any test environment. It is small enough to fit easily into your Whitley Workstation chamber for use with organisms requiring the strict atmosphere. With a footprint marginally larger than that of the microplate it shakes, the Orbis offers the most advance solution for your shaking applications. The counter-balanced orbital movement guarantees a stable, quiet and life long operation. The Orbis shaker can be operated as a microtube shaker when used with an accessory tube platform.

orbis_shaker

- Basket tag set.

20 x 7 colors, perfect for organizing your chamber.

basket_tag

-10 plate Petri dish holder.


-20 plate Petri dish holder.

Used in conjunction with the 20 Plate Adaptor Kits


-30 plate Petri dish holder.

For users with an Airlock Module.

-Whitley Workstation 20 plate Adaptor kit.

Converts each porthole to be capable of transferring up to 20 plates in or out of the workstation at any one time.

20_plate_option

-Whitley Workstation Trolley.

A purpose-designed tubular steel trolley of welded construction with white powder-coated finish, equipped with heavy duty castors for ease of mobility. Available for 500 and 1000 workstations. (Whitley Workstation MG-1000 trolley, with airlock extension shown)

 

-Whitley Workstation Airlock Trolley.

Converts any MACS 500 or 1000 trolley to accommodate an airlock.

trolley

Whitley Petrifoto Plate Imaging System

The Whitley Petrifoto System is a fantastic new accessory for the range of Whitley Workstations. The product fits inside a workstation and enables you to take detailed photographs of organisms growing on Petri dishes during incubation. This is ideal when colony development needs capturing throughout the incubation cycle and is a great tool for teaching and documentation.

The system uses a quality Canon compact digital camera with auto focus, a wide angle zoom lens and a 12.1 megapixel high resolution sensor, all designed to elicit a good quality image frοm even the most amateur of photographers. The camera can also be used independently of the imaging system, either inside or outside the workstation.

This robust unit is small enough to pass through the airlock on the Whitley A35 and A45 Workstations but is large enough to feature an innovative lighting system. The 3D light box contains 64 long life LEDs to provide even illumination. It has underside and side lighting that can be controlled independently to accommodate all agar and colony types. The Petrifoto System comes with an SD memory card and is compatible with Eye-Fi wireless memory cards to allow automatic image transmission to an external PC or MAC. This product can be retrofitted using the spare cable gland on your workstation.

Petrifoto system web

Petrifoto image web

Regulators Available for the MG500:


 

Forged Brass Body
Stainless Steel Diaphragms
Diaphragm Valve
0-125psig Delivery Pressure Range
0-200psig Delivery Pressure Gauge
0-4000psig Cylinder Pressure Gauge
6MM Quick Connect Outlet
CGA 350 for Hydrogen



Forged Brass Body
Stainless Steel Diaphragms
Diaphragm Valve
0-125psig Delivery Pressure Range
0-200psig Delivery Pressure Gauge
0-4000psig Cylinder Pressure Gauge
6MM Quick Connect Outlet
CGA 580 for Inerts (N2, Ar, He)

800regulator

Auto-Switching Regulator

Don't compromise your workstation environment by running out of gas. Our new auto-switching regulator allows you to connect to multiple gas tanks. If the first tank runs out, the regulator automatically switches over to the next tank. This also allows users to change out empty tanks without having to disconnect the gas supply frοm the workstation.

The SwitchPro System safely minimizes repetitive cylinder changeout labor and offers a safe and efficient method of connecting multiple cylinders to a common gas supply
line to provide centralized distribution of gas for both high and low purity delivery requirements. Utilizing SwitchPro Manifold Systems for the distribution of gas provides greater safety in the cylinder storage area by reducing repetitive cylinder handling and
also minimizes the risk of ambient contamination within the gas delivery network.

Click below to download literature on this option.

icon Auto Switching Regulators (510.74 kB)

AutoSwitchReg web2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Video


Operational and Instructional Video for the Whitley Anaerobic Workstation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

contactus

Microbiology International
5111 Pegasus Ct.
Suite H
Frederick MD 21704

p:800EZMICRO (396-4276)
p:(301)662-6835
f:(301)662-8096

©2011 Microbiology International
Automating the world, one lab at a time

Privacy Policy

About Us